China Knee-type automatic disconnector Manufacturer, Supplier, Factory

Every single member from our large efficiency profits team values customers' requirements and organization communication for Knee-type automatic disconnector,Knee-type safety disconnector,Knee-type industrial disconnector,Knee-type panel disconnector,Knee-type rotary disconnector, In addition, we would properly guideline the shoppers about the application techniques to adopt our products and solutions as well as the way to select appropriate materials.
Knee-type automatic disconnector, Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.

Hot Products

  • 145KV 3150A Earthing switch

    145KV 3150A Earthing switch

    145KV 3150A Earthing switch,The neutral point serves various functions, contributing to distinct technical characteristics and operational requirements. The BJ-type transformer neutral point gap grounding protection device plays a crucial role in preserving operational reliability, equipment insulation, and protective measures to ensure consistent performance.
  • Low voltage Active power flter APF/SVG

    Low voltage Active power flter APF/SVG

    Harmonic compensation: Low voltage Active power flter APF/SVG can simultaneously filter out 2-50 harmonics. Rapid response and instant governance. Reactive power compensation: capacitive inductive (-1~1) infinite compensation. The design lifespan is greater than 100000 hours (more than ten years).
  • 126KV Outdoor high-voltage SF6 circuit breaker

    126KV Outdoor high-voltage SF6 circuit breaker

    126KV Outdoor high-voltage SF6 circuit breaker is a high-voltage, three-phase AC 50Hz switchgear designed for outdoor use, ideal for controlling and protecting 126kV transmission and transformation systems. Additionally, it can function as a contact breaker and opener group. This circuit breaker utilizes an intelligent arc extinguishing principle that combines thermal expansion with auxiliary blowing, and features a CTB-1 operating mechanism. It meets the standards outlined in GB1984-2003 for AC high-voltage circuit breakers and is compliant with the International Electrotechnical Commission's IEC62271-100:2001 standard for high-voltage AC circuit breakers and control equipment.
  • 72.5KV 1600amp Outdoor SF6 high-voltage tank circuit breaker

    72.5KV 1600amp Outdoor SF6 high-voltage tank circuit breaker

    The 72.5KV 1600amp Outdoor SF6 high-voltage tank circuit breaker is a unique electrical switch used to disrupt high-voltage electric circuits when faults occur or for regular switching tasks. It relies on sulfur hexafluoride (SF6) gas enclosed in a sealed tank to extinguish arcs and provide insulation. This particular circuit breaker is specially designed for outdoor placement in electrical substations and power distribution systems.
  • DZ47LE-63 RCCB Residual Current Circuit Breaker

    DZ47LE-63 RCCB Residual Current Circuit Breaker

    This circuit breaker is a multifunctional low-voltage protection device designed for distribution systems with AC 50Hz, rated voltage below 400V, and rated current below 63A. It is suitable for industrial, commercial, and civilian power networks. Its core functions integrate security protection, equipment protection, and intelligent monitoring, which can significantly improve the reliability and operation efficiency of the distribution system. Core functional highlights: 1. Safety protection 1) Personal safety assurance: Through high-precision residual current detection technology (RCD), indirect contact protection is provided, effectively reducing the risk of electric shock. 2) Equipment and line protection: Integrated overload and short circuit dual protection mechanism, accurately cutting off fault current, avoiding electrical fires and equipment damage. 2. Intelligent monitoring and early warning 1) Leakage pre-alarm function: Real-time monitoring of residual current in the circuit. When abnormal leakage (such as insulation degradation) is detected, an alarm signal is output through a passive normally open contact (dry contact). It can be linked to SCADA, fire protection system or sound and light alarm device without an external power supply to achieve early warning of faults and ensure power supply continuity. 2) Flexible threshold configuration: supports custom setting of leakage alarm values, adapting to sensitivity requirements of different scenarios (such as 30mA/100mA adjustable). 3. Diversified control ability Line and motor control: suitable for occasional switching operations of distribution lines or intermittent start-stop control of small motors, meeting the requirements of nonfrequent operation scenarios. Typical application scenarios: 1) Key power supply areas: places with high requirements for power continuity, such as data centers and hospital IT systems, have alarm nontrip mechanisms to avoid accidental power outages. 2) Equipment protection: Front-end protection for devices such as frequency converters and outdoor electrical cabinets that are susceptible to electrical leakage or environmental impact. 3) Intelligent operation and maintenance: By connecting to the building management system (BMS) through touch signals, remote monitoring and preventive maintenance can be achieved. Product advantages: 1) High reliability: thermal magnetic double trip structure, balancing overload delay protection and short-circuit instantaneous action characteristics. 2) Flexible expansion: an optional communication module, supporting remote status monitoring and fault diagnosis. 3) Easy installation: Standardized modular design, compatible with mainstream rail installation, suitable for compact distribution boxes. Summary: This circuit breaker is designed with the concept of "warning first, safety oriented", which ensures the safety of personnel and equipment while maximizing the stability of system operation. It is the preferred protective device for modern intelligent distribution systems.
  • 12KV 3150A Medium Voltage Electrical Switchgear Gas Insulation Switchgear

    12KV 3150A Medium Voltage Electrical Switchgear Gas Insulation Switchgear

    In recent years, with the progress of society, economy, and technology, engineering construction has become increasingly intricate. There is a rising demand for compact switch equipment that is low-maintenance and smart. Domestic and international switch manufacturers are working on 12KV 3150A Medium Voltage Electrical Switchgear Gas Insulation Switchgear, known as gas-insulated switchgear (C-GIS). This type of switchgear encases high-voltage elements like busbars, circuit breakers, isolating switches, and power cables in a shell with reduced gas pressure..

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept