China ring main system of distribution Manufacturer, Supplier, Factory

We will devote ourselves to providing our esteemed customers with the most enthusiastically thoughtful services for ring main system of distribution,hv ring main unit,metered ring main unit,ring main unit outdoor,rmu 3 way, We now have substantial goods source and also the rate is our advantage. Welcome to inquire about our merchandise.
ring main system of distribution, Welcome to visit our company, factory and our showroom where displays various hair merchandise that will meet your expectation. Meanwhile, it is convenient to visit our website, and our sales staff will try their best to deliver you the best service. Make sure you contact us if you require more information. Our aim is to help customers realize their goals. We're making great efforts to achieve this win-win situation.

Hot Products

  • 40.5KV 3150 amp Outdoor ceramic column HV Vacuum Circuit Breaker

    40.5KV 3150 amp Outdoor ceramic column HV Vacuum Circuit Breaker

    The ZW7-36 series 40.5KV 3150 amp Outdoor ceramic column HV Vacuum Circuit Breaker is engineered for out door in a three-phase alternating current 50Hz high-voltage switchgear arrangement. It is capable of handling a range of electrical currents, including load, overload, and short-circuit currents, in power distribution and transmission systems operating at 36KV
  • 12KV 1600A Medium Voltage Gas Insulated Electrical Switchgear

    12KV 1600A Medium Voltage Gas Insulated Electrical Switchgear

    The advancement of society, economy, and technology has led to increased complexity in engineering construction. There is a growing demand for compact, low-maintenance, and intelligent switch products. Both domestic and foreign switch manufacturers are actively developing 12KV 1600A Medium Voltage Gas Insulated Electrical Switchgear (C-GIS), also known as gas-insulated switchgear. Gas-insulated switchgear refers to the encapsulation of high-voltage components, such as busbars, circuit breakers, isolating switches, and power cables, within a shell that maintains a lower gas pressure.
  • 126KV Outdoor high-voltage SF6 circuit breaker

    126KV Outdoor high-voltage SF6 circuit breaker

    126KV Outdoor high-voltage SF6 circuit breaker is a high-voltage, three-phase AC 50Hz switchgear designed for outdoor use, ideal for controlling and protecting 126kV transmission and transformation systems. Additionally, it can function as a contact breaker and opener group. This circuit breaker utilizes an intelligent arc extinguishing principle that combines thermal expansion with auxiliary blowing, and features a CTB-1 operating mechanism. It meets the standards outlined in GB1984-2003 for AC high-voltage circuit breakers and is compliant with the International Electrotechnical Commission's IEC62271-100:2001 standard for high-voltage AC circuit breakers and control equipment.
  • 145KV 3150A Centre-break two post disconnector

    145KV 3150A Centre-break two post disconnector

    The 145KV 3150A Centre-break two post disconnector GW4 disconnector's conductive tube boasts a distinctive aluminum profile structure that enhances heat dissipation and fluid flow. This design minimizes the impact of the skin effect, allowing for. The tube's unique design makes it suitable for specific applications. Our product features state-of-the-art silver dedication to quality. This technology improves the adhesion of the silver plating layer, ensuring it meets standards. With appropriate contact pressure, the wear resistance of the contacts is improved, ensuring the silver plating layer remains intact even after extended use, providing long-term peace of mind. The soft connection, made of copper, features a silver-plated conductive contact surface, ensuring excellent conductivity and strong fluid capacity.
  • Arc extinction and harmonic elimination cabinet

    Arc extinction and harmonic elimination cabinet

    Arc extinction and harmonic elimination cabinet During regular functioning, the microcomputer controller constantly monitors the voltage signal received from PT. Suppose the system experiences PT disconnection, single-phase metal grounding, or single-phase arc grounding. In that case, the auxiliary secondary open triangle voltage will promptly shift from a low to a high level. The microcomputer controller will then activate. It will determine the type and phase discrepancy based on the alteration in the PT secondary voltage
  • Energy storage current conversion voltage upgrade integrated cabinet

    Energy storage current conversion voltage upgrade integrated cabinet

    The Energy storage current conversion voltage upgrade integrated cabinet includes dry-type transformers, PCS, high and low voltage switchgear, etc., with a voltage level of 6-35KV and a capacity range of 0.5-3.75MW.