China Outdoor DC disconnect Manufacturer, Supplier, Factory

To continually improve the management procedure by virtue in the rule of "sincerely, great religion and good quality are the base of company development", we commonly absorb the essence of associated products and solutions internationally, and regularly build new solutions to meet the calls for of consumers for Outdoor DC disconnect,Outdoor fused disconnect,Outdoor non-fusible disconnect,Outdoor rotary disconnect switch,Outdoor motor disconnect, We are really proud of your great name from our shoppers for our products' reputable quality.
Outdoor DC disconnect, We put the product quality and customer's benefits to the first place. Our experienced salesmen supply prompt and efficient service. Quality control group make sure the best quality. We believe quality comes from detail. If you have demand, let us work together to get success.

Hot Products

  • DZ47LE-63 RCCB Residual Current Circuit Breaker

    DZ47LE-63 RCCB Residual Current Circuit Breaker

    This circuit breaker is a multifunctional low-voltage protection device designed for distribution systems with AC 50Hz, rated voltage below 400V, and rated current below 63A. It is suitable for industrial, commercial, and civilian power networks. Its core functions integrate security protection, equipment protection, and intelligent monitoring, which can significantly improve the reliability and operation efficiency of the distribution system. Core functional highlights: 1. Safety protection 1) Personal safety assurance: Through high-precision residual current detection technology (RCD), indirect contact protection is provided, effectively reducing the risk of electric shock. 2) Equipment and line protection: Integrated overload and short circuit dual protection mechanism, accurately cutting off fault current, avoiding electrical fires and equipment damage. 2. Intelligent monitoring and early warning 1) Leakage pre-alarm function: Real-time monitoring of residual current in the circuit. When abnormal leakage (such as insulation degradation) is detected, an alarm signal is output through a passive normally open contact (dry contact). It can be linked to SCADA, fire protection system or sound and light alarm device without an external power supply to achieve early warning of faults and ensure power supply continuity. 2) Flexible threshold configuration: supports custom setting of leakage alarm values, adapting to sensitivity requirements of different scenarios (such as 30mA/100mA adjustable). 3. Diversified control ability Line and motor control: suitable for occasional switching operations of distribution lines or intermittent start-stop control of small motors, meeting the requirements of nonfrequent operation scenarios. Typical application scenarios: 1) Key power supply areas: places with high requirements for power continuity, such as data centers and hospital IT systems, have alarm nontrip mechanisms to avoid accidental power outages. 2) Equipment protection: Front-end protection for devices such as frequency converters and outdoor electrical cabinets that are susceptible to electrical leakage or environmental impact. 3) Intelligent operation and maintenance: By connecting to the building management system (BMS) through touch signals, remote monitoring and preventive maintenance can be achieved. Product advantages: 1) High reliability: thermal magnetic double trip structure, balancing overload delay protection and short-circuit instantaneous action characteristics. 2) Flexible expansion: an optional communication module, supporting remote status monitoring and fault diagnosis. 3) Easy installation: Standardized modular design, compatible with mainstream rail installation, suitable for compact distribution boxes. Summary: This circuit breaker is designed with the concept of "warning first, safety oriented", which ensures the safety of personnel and equipment while maximizing the stability of system operation. It is the preferred protective device for modern intelligent distribution systems.
  • Modular AC metal enclosed Ring main unit RMU

    Modular AC metal enclosed Ring main unit RMU

    HXGN-12 switchgear Modular AC metal enclosed Ring main unit RMU is a high-voltage AC complete set designed for a three-phase AC ring network, terminal distribution network, and industrial electrical equipment. It is suitable for power distribution and protection and can be installed in substations. It complies with national standards GB3906 and IEC60298, as well as DL/T402 and DL/T404 standards, and meets the requirements of "five-proof" blocking.
  • 12KV vacuum circuit breaker with Isolation and Grounding

    12KV vacuum circuit breaker with Isolation and Grounding

    This product 12KV vacuum circuit breaker with Isolation and Grounding offers numerous benefits, including simplicity of installation, reduced maintenance needs, a reassuringly extended lifespan, compact design, affordability, and reliability. The product complies with the technical standards of GB1984-89 and GB/T1984-2003 for AC high-voltage circuit breakers. Key specifications include a main circuit capacity of 630A-20KA and 25KA, with a mechanical lifespan of 10,000 operations. The grounding circuit can withstand 20KA, with a mechanical lifespan of 10,000 operations for the circuit breaker and 3,000 operations for isolation and grounding.
  • 12KV 1250AMP Vertical break two post isolating switch

    12KV 1250AMP Vertical break two post isolating switch

    The 12KV 1250AMP Vertical break two post isolating switch is specifically designed for use in 10(12,15,24)KV high voltage transmission and distribution lines. These switches serve the purpose of disconnecting and connecting single-phase or three-phase circuits without load and voltage. They are particularly engineered for single-phase application within a three-phase circuit system and are characterized by a simple and cost-effective design, ensuring ease of operation and maintenance. The switches are available in a range of rated current options, including 200400,600,630,800, and 1000,1250 amperes, providing the flexibility to select the most suitable option based on specific requirements. They are comprised of a base, pillar insulator, conductive part, and mechanism part.
  • 126KV 1250A Neutral point disconneetor

    126KV 1250A Neutral point disconneetor

    126KV 1250A Neutral point disconneetor is specifically engineered for application in high-voltage transmission lines operating under no-load conditions. Its primary function is to provide electrical isolation during the maintenance of circuit breakers and other associated equipment, thereby ensuring compliance with insulation distance requirements and enhancing overall operational safety.
  • 24KV assembly type indoor vacuum circuit breaker

    24KV assembly type indoor vacuum circuit breaker

    24KV assembly type indoor vacuum circuit breaker, a robust solution for your electrical equipment, is designed for indoor use with a rated voltage of 12kV. It operates at a frequency of three-phase AC 50Hz and is suitable for industrial and mining enterprises, power plants, and substations. This circuit breaker is not only reliable but also ideal for locations that require frequent operation, providing you with reassurance. It can be mounted in a switch cabinet or placed on a handcart, and it is simple to install.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept