China Medium voltage outdoor load break switch Manufacturer, Supplier, Factory

To be a result of ours specialty and repair consciousness, our corporation has won an excellent reputation amongst customers all around the entire world for Medium voltage outdoor load break switch,AMP outdoor circuit breaker enclosure,SF6 outdoor switchgear,Outdoor circuit breaker box,Medium voltage outdoor power distribution, How about to start your great enterprise with our corporation? We've been prepared, qualified and fulfilled with pride. Let’s start our new business with new wave.
Medium voltage outdoor load break switch, Relying on superior quality and excellent post-sales, our items sell well in America, Europe, the Middle East and South Africa. We're also the appointed OEM factory for several worlds' famous merchandise brands. Welcome to contact us for further negotiation and cooperation.

Hot Products

  • DZ47s-63 MCB Miniature Circuit Breaker 4.5KA Breaking Capacity

    DZ47s-63 MCB Miniature Circuit Breaker 4.5KA Breaking Capacity

    This series of miniature circuit breakers consists of a plastic casing, overcurrent release, operating mechanism, contacts, and arc extinguishing system. The shell is made of high-strength and highly flame-retardant plastic. A multi-pole circuit breaker is assembled from multiple single poles, with the release connected by a linkage rod and the handle connected by a linkage cover, ensuring consistency in the on-off of each pole.
  • 12KV 2000A Armored Removable Ac Metal Enclosed Switchgear

    12KV 2000A Armored Removable Ac Metal Enclosed Switchgear

    The KYN28-12(Z) 12KV 2000A Armored Removable Ac Metal Enclosed Switchgear is designed for use in three-phase AC power systems operating at a rated voltage of 12kV and frequency of 50Hz. This equipment is utilized for the reception, distribution, and management of electrical power, as well as for controlling, safeguarding, and monitoring circuits.
  • Low voltage Intelligent power quality hybrid compensation cabinet

    Low voltage Intelligent power quality hybrid compensation cabinet

    Low voltage Intelligent power quality hybrid compensation cabinet (after combining the complete set of devices) is installed in the cabinet, equipped with incoming circuit breakers and fast melting. Capacitor capacity can be any combination of 5kvar-60kvar; APF or SVG modules with capacities of 50A (35kvar), 100A (70kvar), and 100kvar are optional. Rear ventilation design with ventilation overcurrent mesh holes.
  • 40.5KV 3150A V-type centre breaker disconnector

    40.5KV 3150A V-type centre breaker disconnector

    The GW5 outdoor isolation switch is a high-voltage electrical device designed to meet specific structural requirements. It consists of three independent single-phase isolation switches, making it a versatile and reliable option for various applications. The device complies with the standards outlined in the JB520-64 "AC High Voltage Isolation Switch" and features an additional grounding knife device for added safety. The CS-G manual operating mechanism is available in three variations: ungrounded, single-grounded, and double-grounded, providing users with options to suit their needs.
  • 12KV Outdoor Demarcation Vacuum Load Break Switch LBS

    12KV Outdoor Demarcation Vacuum Load Break Switch LBS

    The FZW28-12F 12KV Outdoor Demarcation Vacuum Load Break Switch LBS, as the boundary, is designed for outdoor installation on columns and can be operated manually or electrically. This switch utilizes the Corporation's VSP5-12 technology, making it a maintenance-free load switch. It uses vacuum arc extinguishing and SF6 gas for ground and phase insulation. This product conforms to the standards of GB3804 for high voltage AC load switch and GBT high voltage switchgear and control equipment.
  • DZ47LE-63 RCCB Residual Current Circuit Breaker

    DZ47LE-63 RCCB Residual Current Circuit Breaker

    This circuit breaker is a multifunctional low-voltage protection device designed for distribution systems with AC 50Hz, rated voltage below 400V, and rated current below 63A. It is suitable for industrial, commercial, and civilian power networks. Its core functions integrate security protection, equipment protection, and intelligent monitoring, which can significantly improve the reliability and operation efficiency of the distribution system. Core functional highlights: 1. Safety protection 1) Personal safety assurance: Through high-precision residual current detection technology (RCD), indirect contact protection is provided, effectively reducing the risk of electric shock. 2) Equipment and line protection: Integrated overload and short circuit dual protection mechanism, accurately cutting off fault current, avoiding electrical fires and equipment damage. 2. Intelligent monitoring and early warning 1) Leakage pre-alarm function: Real-time monitoring of residual current in the circuit. When abnormal leakage (such as insulation degradation) is detected, an alarm signal is output through a passive normally open contact (dry contact). It can be linked to SCADA, fire protection system or sound and light alarm device without an external power supply to achieve early warning of faults and ensure power supply continuity. 2) Flexible threshold configuration: supports custom setting of leakage alarm values, adapting to sensitivity requirements of different scenarios (such as 30mA/100mA adjustable). 3. Diversified control ability Line and motor control: suitable for occasional switching operations of distribution lines or intermittent start-stop control of small motors, meeting the requirements of nonfrequent operation scenarios. Typical application scenarios: 1) Key power supply areas: places with high requirements for power continuity, such as data centers and hospital IT systems, have alarm nontrip mechanisms to avoid accidental power outages. 2) Equipment protection: Front-end protection for devices such as frequency converters and outdoor electrical cabinets that are susceptible to electrical leakage or environmental impact. 3) Intelligent operation and maintenance: By connecting to the building management system (BMS) through touch signals, remote monitoring and preventive maintenance can be achieved. Product advantages: 1) High reliability: thermal magnetic double trip structure, balancing overload delay protection and short-circuit instantaneous action characteristics. 2) Flexible expansion: an optional communication module, supporting remote status monitoring and fault diagnosis. 3) Easy installation: Standardized modular design, compatible with mainstream rail installation, suitable for compact distribution boxes. Summary: This circuit breaker is designed with the concept of "warning first, safety oriented", which ensures the safety of personnel and equipment while maximizing the stability of system operation. It is the preferred protective device for modern intelligent distribution systems.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept