We keep on with the principle of "quality initial, service very first, ongoing improvement and innovation to meet the customers" for the administration and "zero defect, zero complaints" as the quality objective. To fantastic our assistance, we give the goods while using the fantastic high quality at the reasonable price for Ring main unit enclosure,Ring main unit,RMU,Electrical ring main unit,Ring main unit switchgear, For more details, please get hold of us as soon as possible!
Ring main unit enclosure, We will continue to devote ourselves to market & product development and build a well-knit service to our customer to create a more prosperous future. Make sure you contact us today to find out how we can work together.

Hot Products

  • 40.5KV 630A Neutral point disconnector

    40.5KV 630A Neutral point disconnector

    The The GW8 series neutral point disconnecting switch is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch. is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch.
  • Electric energy Metering box

    Electric energy Metering box

    The DJK series Electric energy Metering box is a versatile and reliable solution for electricity metering in high-rise buildings and residential areas. With a maximum current capacity of 63A, it can accommodate a variety of household needs. Additionally, its design can be customized to fit specific requirements, including the number of meter positions and external installation features. This meter box is ideal for households that require accurate and efficient electricity metering.
  • 40.5KV 4000A Double-break three post disconnector

    40.5KV 4000A Double-break three post disconnector

    40.5KV 4000A Double-break three post disconnector is designed to enhance the efficiency of indoor stations by reducing the distance and station arrangement. Its robust motor performance resistance is achieved through the electric rod's self-rotation and switching structure, along with its self-locking function. This disconnector is capable of withstanding motor, wind pressure, earthquake, and other external forces. Additionally, its sliding rotation method ensures a strong self-clean ability.
  • Photovoltaic grid connected cabinet

    Photovoltaic grid connected cabinet

    BWG Photovoltaic grid connected cabinet is an important component that undertakes centralized inverters and step-up transformers or AC combiner box step-up transformers. The incoming line of this photovoltaic grid connected cabinet uses a short-circuit breaker input or direct input, and the output uses a circuit breaker or load isolation switch. The busbar is connected with electroplated or purified wire, and provides secondary lightning protection. The maximum rated voltage of the system is AC690V, and the protection level is | P40 indoors and | P65 outdoors; The cables for secondary measurement and control include cables with a current greater than 2.5mm2, cables with a voltage of 1.5mm2, and cables with a control voltage greater than 1.0mm2. The measuring current transformer is a current transformer of level 0.5, and the measuring current transformer is a current transformer of level 0.25. Relevant functions can also be added according to customer requirements. This product adopts professional electrical design, is simple, beautiful, convenient for on-site wiring and maintenance, and ensures long-term stable operation of the equipment.
  • 12kv ourdoor mv vcb vacuum circuit breaker

    12kv ourdoor mv vcb vacuum circuit breaker

    The ZW32 series 12kv ourdoor mv vcb vacuum circuit breaker, a versatile and reliable piece of equipment, is designed with the user's convenience in mind. With a rated voltage of 12kV and a three-phase alternating current of 50Hz, it efficiently opens and closes load current, overload current, and short circuit current in power systems. Its suitability extends to power distribution systems in substations, industrial and mining enterprises, and rural areas where the power grid is frequently operated. This circuit breaker's unique selling points include a compact design, lightweight construction, and anti-condensation properties. However, its most appealing feature is its low maintenance requirements, making it a cost-effective solution for your power distribution needs.
  • DZ20LE series MCCB Leakage circuit breaker

    DZ20LE series MCCB Leakage circuit breaker

    This product is designed for 50Hz AC power distribution networks with a rated operational voltage of 380V and a rated current up to 630A. It provides reliable indirect contact protection for personnel and effectively prevents fire hazards caused by ground fault currents resulting from equipment insulation failures. The device incorporates multiple protection mechanisms to deliver precise overload and short-circuit protection for power distribution lines and supply equipment, while featuring circuit status monitoring capabilities. Under normal operating conditions, it can serve as an infrequent switching device for distribution circuits and provide occasional motor starting control functionality. The integrated design combines electrical safety protection with equipment management requirements, significantly enhancing the operational reliability of power distribution systems and fire prevention capabilities.