Bear "Customer very first, Quality first" in mind, we work closely with our customers and supply them with efficient and professional services for Double Pole Isolating Switch,Single Pole Isolating Switch,Outdoor Isolating Switch,Enclosed Isolating Switch,Lockable Isolating Switch, We have been self-assured to make excellent achievements within the future. We've been looking forward to becoming one within your most trusted suppliers.
Double Pole Isolating Switch, With the superior and exceptional service, we've been well developed along with our customers. Expertise and know-how ensure that we are always enjoying the trust from our customers in our business activities. "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your service. Contact Us Today For further information, contact us now.

Hot Products

  • DZ47LE-63 RCCB Residual Current Circuit Breaker

    DZ47LE-63 RCCB Residual Current Circuit Breaker

    This circuit breaker is a multifunctional low-voltage protection device designed for distribution systems with AC 50Hz, rated voltage below 400V, and rated current below 63A. It is suitable for industrial, commercial, and civilian power networks. Its core functions integrate security protection, equipment protection, and intelligent monitoring, which can significantly improve the reliability and operation efficiency of the distribution system. Core functional highlights: 1. Safety protection 1) Personal safety assurance: Through high-precision residual current detection technology (RCD), indirect contact protection is provided, effectively reducing the risk of electric shock. 2) Equipment and line protection: Integrated overload and short circuit dual protection mechanism, accurately cutting off fault current, avoiding electrical fires and equipment damage. 2. Intelligent monitoring and early warning 1) Leakage pre-alarm function: Real-time monitoring of residual current in the circuit. When abnormal leakage (such as insulation degradation) is detected, an alarm signal is output through a passive normally open contact (dry contact). It can be linked to SCADA, fire protection system or sound and light alarm device without an external power supply to achieve early warning of faults and ensure power supply continuity. 2) Flexible threshold configuration: supports custom setting of leakage alarm values, adapting to sensitivity requirements of different scenarios (such as 30mA/100mA adjustable). 3. Diversified control ability Line and motor control: suitable for occasional switching operations of distribution lines or intermittent start-stop control of small motors, meeting the requirements of nonfrequent operation scenarios. Typical application scenarios: 1) Key power supply areas: places with high requirements for power continuity, such as data centers and hospital IT systems, have alarm nontrip mechanisms to avoid accidental power outages. 2) Equipment protection: Front-end protection for devices such as frequency converters and outdoor electrical cabinets that are susceptible to electrical leakage or environmental impact. 3) Intelligent operation and maintenance: By connecting to the building management system (BMS) through touch signals, remote monitoring and preventive maintenance can be achieved. Product advantages: 1) High reliability: thermal magnetic double trip structure, balancing overload delay protection and short-circuit instantaneous action characteristics. 2) Flexible expansion: an optional communication module, supporting remote status monitoring and fault diagnosis. 3) Easy installation: Standardized modular design, compatible with mainstream rail installation, suitable for compact distribution boxes. Summary: This circuit breaker is designed with the concept of "warning first, safety oriented", which ensures the safety of personnel and equipment while maximizing the stability of system operation. It is the preferred protective device for modern intelligent distribution systems.
  • 126KV HV Outdoor high-voltage SF6  single-phase circuit breaker

    126KV HV Outdoor high-voltage SF6 single-phase circuit breaker

    This 126KV HV Outdoor high-voltage SF6 single-phase circuit breaker is suitable for use in 72.5KV and 126KV three-phase AC 50HZ transmission and transformation systems. Its primary purpose is to regulate and safeguard these systems, but it can also function as a contact breaker and opener group, offering versatility in its applications.
  • 12KV 1250AMP Vertical break two post isolating switch

    12KV 1250AMP Vertical break two post isolating switch

    The 12KV 1250AMP Vertical break two post isolating switch is specifically designed for use in 10(12,15,24)KV high voltage transmission and distribution lines. These switches serve the purpose of disconnecting and connecting single-phase or three-phase circuits without load and voltage. They are particularly engineered for single-phase application within a three-phase circuit system and are characterized by a simple and cost-effective design, ensuring ease of operation and maintenance. The switches are available in a range of rated current options, including 200400,600,630,800, and 1000,1250 amperes, providing the flexibility to select the most suitable option based on specific requirements. They are comprised of a base, pillar insulator, conductive part, and mechanism part.
  • Low voltage Intelligent power quality hybrid compensation cabinet

    Low voltage Intelligent power quality hybrid compensation cabinet

    Low voltage Intelligent power quality hybrid compensation cabinet (after combining the complete set of devices) is installed in the cabinet, equipped with incoming circuit breakers and fast melting. Capacitor capacity can be any combination of 5kvar-60kvar; APF or SVG modules with capacities of 50A (35kvar), 100A (70kvar), and 100kvar are optional. Rear ventilation design with ventilation overcurrent mesh holes.
  • Primary and secondary Fusion ring main unit

    Primary and secondary Fusion ring main unit

    The XGW-12 series Primary and secondary Fusion ring main unit (switching station) is a company that adopts advanced foreign technology and is based on various regional distribution networks in China. The development and production of inflatable outdoor ring main unit based on the characteristics and actual situation of urban distribution network cable transformation. The XGW-12 series Primary and secondary Fusion ring main unit (switch station) adopts HTN-12 environmentally friendly gas ring main unit switchgear. This switchgear has the advantages of modularity, scalability, full insulation, full sealing, safety and reliability, maintenance-free operation, wireless temperature measurement, online monitoring devices, etc. It is suitable for any harsh environment and is widely used in industrial parks, residential areas, streets, airports, various buildings, bustling commercial centers, and other places.
  • DZ20 series MCCB Moulded Case Circuit Breaker

    DZ20 series MCCB Moulded Case Circuit Breaker

    The DZ20 series plastic shell circuit breaker (hereinafter referred to as the circuit breaker) is suitable for distribution lines with AC 50Hz, rated current up to 1250A, rated insulation voltage of 660V, rated working voltage of 380V (400V) and below, as overload, short circuit and undervoltage protection for distributed electrical energy, lines and power equipment. Among them, the Y, J, and G type circuit breakers with rated currents of 225A and Y type 400A can also be used to protect motors. Under normal circumstances, the circuit breaker can be used for infrequent switching of lines and infrequent starting of motors. The product meets the standards of JB8589, GB14048.2, and IEC947-2.